• TEL: 0086-13083697781

optimization and model of laminar cooling control system

Get Price

We can supply you need optimization and model of laminar cooling control system.

ADVANCED CONTROL OF COILING TEMPERATURE IN

modernization which was completed in 2005. This included new laminar strip cooling system with new control system. The main objectives were to produce special steel grades which meet specific structural requirements such as DP, API, and TRIP grades and achieve tight coiling temperature tolerances. Advanced coiling temperature modeling and on-line Case-Based Modeling of the Laminar Cooling Process in a Accurate mathematical modeling of the laminar cooling process is difficult due to its complex nature (e.g., highly nonlinear, time varying, and spatially varying). A case-based temperature prediction model is developed for the laminar cooling process using case-based reasoning (CBR) and the dynamical process model.

Distributed Model Predictive Control for PlantWide Systems

Aug 07, 2015 · Professor Li received his Ph.D in Computer and System Science from Nankai University in 1996. He has published five books and more than three hundred papers in journals/conferences, which describe his research accomplishments and interests in predictive control, distributed model predictive control, intelligent adaptive control, and fuzzy HOLISTIC OPTIMIZATION OF DATA CENTER COOLING control for the studied data center cooling system. Model predictive control (MPC) has been widely studied for optimal control. Though it can achieve a good performance theoretically, formulating a precise and real-time model is often not easy especially for complex systems, such as data center cooling systems involving stratified airflow. HVAC system modeling and optimization:a data HVAC SYSTEM MODELING AND OPTIMIZATION:A DATA-MINING APPROACH . by . Fan Tang . A thesis submitted in partial fulfillment . of the requirements for the Master of Science

Hot strip laminar cooling control model Request PDF

Since hot-rolled strip laminar cooling (HSLC) process is a large-scale, nonlinear system, a distributed model predictive control (DMPC) framework is proposed for computational reason and enhancing Hot-Rolled Strip Laminar Cooling Process Plant-Wide In order to improve the accuracy of temperature prediction model of laminar flow cooling system, a new model is introduced to control the temperature of steel plate cooled down by laminar flow. Hybrid intelligent control strategy of the laminar cooling Tan, M.H., Chai, T.Y.:Laminar Cooling Process Model Development Using RBF Networks. ISNN 2006, In Press Google Scholar Digital Library Shan, X.:Transformation and Development of the Cooling Control System of the 2050mm Baosteel Hot Strip Mill.

Hybrid intelligent control strategy of the laminar cooling

Tan, M.H., Chai, T.Y.:Laminar Cooling Process Model Development Using RBF Networks. ISNN 2006, In Press Google Scholar Digital Library Shan, X.:Transformation and Development of the Cooling Control System of the 2050mm Baosteel Hot Strip Mill. Mathematical Modeling and Experimental Study of model of inverse heat conduction problem was built and the laminar cooling process was studied by experiment. The main works included data acquisition, inverse heat conduction problem model and verification of algorithms. The research results show that the rate of cooling is proportional to the cooling water flow, and the effect of cooling On-Line Optimization of Coiling Temperature Control on Run Cooling strategies, elements tracking, and dynamic correction are employed in the control system. In addition, the model optimization and soft-measure method are also introduced in the study. Rolling tests with various grades of steel covering a wide range of thickness show that the developed model can improve the accuracy of coiling temperature control to obtain an uniform mechanical properties.

Optimal Temperature Tracking for Accelerated Cooling

This paper is concerned with the development of a control system for tracking of a desired temperature-time profile for accelerated cooling processes in hot rolling of steel. Control of temperature during cooling is essential for achieving desired mechanical and metallurgical properties of steel. The cooling process is represented by the heat equation in Lagrangian coordinates which is Optimization of cooling towers - Control GlobalNov 19, 2018 · This controller keeps the range of the system constant by adjusting the speed of the cooling water pumps. The optimum pump speed is determined by a valve position controller (VPC-4), which serves to minimize the pressure drops across all cooling water valves in the plant by opening up all of them until the most open one reaches 90% opening. Optimization of multi-V filter design for airliner 1 1 Optimization of multi-V filter design for airliner 2 environmental control system using an empirical model 3 4 Xuan Liua, Xin Zhanga, Sumei Liua,b*, Junjie Liua, Qingyan Chenb 5 aTianjin Key Lab of Indoor Air Environmental Quality Control, School of Environmental Science 6 and Engineering, Tianjin University, Tianjin 300072, China 7 bSchool of Mechanical Engineering, Purdue University

Research for Coiling Temperature Control System and

Based on the devices, instruments and control requirements of 1150mm hot strip steel mill in a certain actual Iron & Steel Co., the laminar cooling control system is designed, including hardware Strip Cooling Spraying Systems Co.Laminar Flow Headers. Our laminar flow headers provide consistent and cost-effective sheet cooling on runout tables. Operating at pressures as low as 0.9 psi (0.06 bar), laminar cooling uses water very effectively. The rod-like column of water from solid stream VeeJet® nozzles is superior to U-tube nozzle cooling. Study and Application of the Automotive Control System of The automotive control system of hot strip mill's laminar cooling, including water level control, feedforward control and feedback control of coiling temperature with smith predictor, is introduced. Steady water level can be got by water level control model, which is very important for water flux stabilization and the setup precision of process computer.

INTELLIGENT OPTIMIZATION CONTROL FOR LAMINAR

Keywords:laminar cooling control, distributed control, optimization, modeling, soft sensing, supervisory control. 1. INTRODUCTION The laminar cooling of hot slabs is a key process in hot rolling that not only shortens the cooling time of the slab but also improves the quality of the finished product (Groch, et al., 1990). The process represents

Get Price

We can supply you need optimization and model of laminar cooling control system.